Quick takeaways
Choosing vacuum valves and fittings for a furnace rarely fails on the valve. It fails on the flange: a KF face offered against an ISO-K port, a CF joint that cannot be baked, or a clamp that does not exist above KF63. Each of those is cheap to catch on the drawing and expensive to catch on site. This guide maps the four families EFUN builds — KF, ISO-K, ISO-F and CF — onto the four places a furnace actually needs them, then turns the choice into a purchase order a factory can build from.
A heat treatment furnace is four different vacuum problems inside one vessel. The hot zone wants metal, the pumping line wants speed, the gauge port wants to come off by hand, and the loading door wants to open twice a shift. No single flange family does all four well, so almost every furnace carries two or three of them on the same machine, and the joints between them are where leaks appear.
Every vacuum joint in a furnace seals one of two ways, and that is what settles the temperature it survives, how often it can be opened, and what it costs per cycle.
Elastomer joints press a rubber O-ring between two flat faces. In EFUN’s KF range the O-ring sits inside a centring ring, and the ring is what centres the two flanges before the clamp closes; the catalogue offers Viton or NBR for that ring, with the carrier in aluminium or SS304. The same principle runs through ISO-K and ISO-F, where the O-ring sits either in a centring ring or in a groove machined into the flange face — EFUN lists both, as the plain ISO-F and the grooved ISO-F.
Metal joints crush a gasket instead. A CF joint pulls a copper ring between two knife edges until the copper yields; there is no rubber anywhere in the seal. That is why CF exists: the joint can be baked, and a KF joint cannot.
| Family | What seals it | How it closes | Bakeout headroom |
|---|---|---|---|
| KF | O-ring in a centring ring | One clamp, hand tight | Limited by the O-ring |
| ISO-K | O-ring, centring ring | Double-claw clamp, no bolts | Limited by the O-ring |
| ISO-F | O-ring, plain or grooved face | 4 to 20 bolts | Limited by the O-ring |
| CF | Copper gasket, knife edge | 6 to 32 bolts | All metal, high |
The table only reads one way. A CF joint can be built to survive a bakeout; a KF joint cannot be upgraded into one, because the rubber is the seal rather than a helper. If a furnace cycle includes a hot bake, the joints inside the hot zone have to be CF before anything else is decided.
The three families do not stop at the same size, and that is where most drawings go wrong. EFUN’s KF flanges run from KF10 to KF200, with flange outside diameters from 30 mm at KF10 and KF16 up to 252 mm at KF200. ISO-F bolted flanges run from ISO63 to ISO630, and CF runs from CF16 to CF250.
The body material matters here too. KF and ISO flanges are listed in SS304, 304L and 316L; the CF series adds 316LN, the low-carbon, nitrogen-bearing grade that holds strength after a weld in a furnace frame. If a joint is going to be welded into a chamber wall and then baked repeatedly, that is the grade to ask about, and it is only offered on CF.
One practical note on KF: the family reaches KF200, but the hardware does not stay the same. Up to KF50 the catalogue offers aluminium toggle and rapid clamps you can close by hand; from KF80 upward the only thing that closes the joint is a chain clamp. Plan the access before you plan the flange — a KF100 joint behind a furnace panel needs room for a chain, not a thumb.
Every size and bolt circle in this article is taken from the EFUN vacuum catalogue; if a number has to survive a customer’s inspection, check it there rather than in a blog post.
Bakeout is the number EFUN’s catalogue leaves out, and the one that decides whether a furnace reaches vacuum at all. The physics is simple: an elastomer seal has a temperature ceiling, and a metal seal’s ceiling comes from the copper gasket instead. A CF joint, which is all metal apart from the copper, is the joint you specify when the chamber will be baked. A KF or ISO joint carries rubber in the seal path, so its ceiling belongs to the O-ring, not to the flange.
EFUN’s catalogue lists Viton and NBR for the KF centring rings but does not publish a temperature figure for either. The omission is common in this industry, which is why the figure belongs in the order: ask for the bakeout temperature of the specific seal compound you are buying, on paper, and treat a verbal “it will be fine” as no answer. A Viton seal and an NBR seal look identical in a photograph and behave nothing alike at 150 °C.
Face length is the second silent trap. It is the dimension between the two flange faces of the valve, and it has to match the gap you left in the pipe. EFUN builds two standards of the same KF poppet valve, and they do not measure the same: a GD-J40-KF is 177.7 mm face to face in the USA standard and 185.5 mm in the EURO standard. Same model number stem, two different gaps, 7.8 mm apart. Order the wrong one and it will not fit the space you built for it.
Not every valve type exists in every family, and that decides whether a project is buildable. In EFUN’s range the coverage is uneven in a predictable way: the small elastomer families carry the widest choice, the metal family the fewest bodies.
| Family | Bodies available | Sizes |
|---|---|---|
| KF | Manual and pneumatic poppet (L, Z and Y types), angle valve, ball valve, three-way ball valve, air release valve | KF16 to KF80 |
| ISO | Pneumatic thin angle valve | ISO63 to ISO250 |
| CF | Pneumatic angle valve (thin and cylinder types), manual and pneumatic Y-type poppet | CF16 to CF80 |
| Bolted, no standard flange face | Butterfly valve (manual GI, pneumatic GIQ), gate valve (CC) | GI-25 to GI-400, GIQ-25 to GIQ-800, CC-63B to CC-250B |
The first gap is ISO: there is no ISO ball valve in the range, so a furnace that needs an isolation valve at ISO100 takes a pneumatic angle valve. The second is CF, which stops at CF80 for valves even though CF flanges go to CF250. A CF160 valve is not a catalogue item, so a design that needs one has to isolate somewhere else — a gate valve on the chamber, with CF flanges around it.
If the choice between body types matters more than the flange at this stage, the existing guide to types of vacuum valves and how to select the right one covers that ground; this article only follows the joint.
A furnace is a hot chamber, a cold pumping line, and a set of service ports that a fitter opens with cold hands at two in the morning. Each of those wants a different joint, and the design decision is where to change family.
The chamber port is the one place where CF is almost always the right answer, for a physical reason rather than a fashionable one: it is the joint that sees the bakeout. A CF port is welded or bolted to the chamber wall through a fixed flange with tapped holes, the matching half is a rotatable blank, and a copper gasket is crushed between the two knife edges. Nothing in that stack softens when the furnace heats.
Past CF80 the arithmetic changes, because CF valve bodies are not stocked above that size in the current range. Large furnace chambers often run an ISO-F port instead, accept that the O-ring sets the temperature ceiling, and move the bakeout burden onto a gate valve or a water-cooled baffle. That is a legitimate engineering trade, but it should be a written decision on the drawing, not something discovered when the pump-down stalls.
Behind the isolation valve the rules relax. The foreline, the vent line and the gauge ports sit outside the hot zone, they are opened often, and they are where a fitter works with one hand. KF is the correct family there. It closes with a single clamp and no tools in the sizes involved, which matters more than the price.
Two practical habits save time on a furnace build. Keep every service port on one KF size if the instrumentation allows it, so one clamp and one centring ring fit all of them. And fit a centring ring with the O-ring bonded in rather than a loose ring and a loose O-ring, because the loose pair is what gets dropped behind the furnace at commissioning and replaced with whatever was in the drawer.
These two are the easiest pair in the catalogue to mis-order. An ISO63 port is 63 mm nominal in either form; the flanges bolt to nothing in common. ISO-K closes with a double-claw clamp around two plain flange rims, with a centring ring and O-ring doing the sealing. ISO-F closes with bolts through a drilled flange, and the O-ring sits either in a centring ring or in a groove machined into the face.
| ISO-F size | Bolt holes | Bolt circle (mm) | Flange OD (mm) |
|---|---|---|---|
| ISO63 | 4 × ø9 | 110 | 130 |
| ISO100 | 8 × ø9 | 145 | 165 |
| ISO160 | 8 × ø11 | 200 | 225 |
| ISO200 | 12 × ø11 | 260 | 285 |
| ISO250 | 12 × ø11 | 310 | 335 |
| ISO630 | 20 × ø14 | 720 | 750 |
So “ISO100” on a drawing is not a specification. It is half a specification. The order has to say ISO-K or ISO-F, and if it says ISO-F it should also say whether the face is plain or grooved, because those two do not accept the same hardware. The full set of sizes from ISO63 to ISO630, with every bolt circle, is on the vacuum valve fundamentals side of the library if the sequence of pump-down matters more than the joint.
These three show up again and again on furnace projects that come back for a redesign. None of them is exotic, and none of them survives a careful drawing review.
The flange does not seal anything. The seal seals, and the flange is only the clamp that holds it. Choosing a family first and a compound second is how a furnace ends up with Viton joints in a zone that runs hot enough to harden them into a permanent leak.
Reverse the order. Write the maximum temperature the joint will see during a bake, then pick the compound that survives it, then pick the family that accepts that compound. In EFUN’s range that conversation has only three outcomes: Viton, NBR, or a CF joint with a copper gasket and no rubber at all. Anything else is a special that needs a written answer before it goes on a drawing.
It cannot be done, and no gasket will bridge it. A KF flange is a short spigot with an outer taper that a clamp squeezes; a CF flange is a flat disc with a knife edge and tapped holes. There is no shared surface for either seal to work against, and a homemade adapter between them is a leak path with a bolt pattern.
The catalogue answer is an adapter flange from the adaptor series, which converts one family to another with a proper face on each end. It costs one extra joint in the line and it is the only honest way to join two families. If a drawing shows a KF valve bolted directly to a CF port, that joint will not hold vacuum and no amount of torque will change it.
CF comes in two forms and they are not interchangeable in use. The non-rotatable type has tapped holes and is the half you weld or bolt to the chamber, because it cannot move. The rotatable blank carries the clearance holes and turns, so the bolt holes can be lined up after the parts are in place.
Fit two fixed flanges to each other and the bolt holes have to align perfectly before anything is welded — a tolerance nobody can hold on a fabricated chamber. Fit two rotatable flanges and nothing is located. The rule is one fixed, one loose, per joint, every time. It costs nothing to get right and a weekend to get wrong.
A vacuum order fails in the same place as any other: the buyer writes a size, the factory quotes a size, and the difference surfaces at commissioning. Five lines on a purchase order prevent most of it.
Write the family as well as the size. “ISO63” is ambiguous; “ISO-F, plain face, ISO63” is an order. For KF, the catalogue also runs a compression-adaptor and a hose-adaptor branch, so if the joint ends in a tube rather than a flange, say so on the same line.
Give the model and the face length together, because the model alone does not fix the length. The USA and EURO builds of the same KF poppet valve differ by several millimetres, and a furnace frame has no adjustment for that. If the valve replaces an existing one, measure the old body and put the number on the order; if it is a new build, quote the drawing dimension and ask the supplier to confirm it in the acknowledgement.
Name the compound and the bakeout figure in the same line, so a substitution cannot pass unnoticed. If the answer comes back as “Viton, suitable for vacuum”, ask again with the temperature. A supplier who will not put a number in writing is telling you something useful about the joint.
Then check the delivery against the order. The drawing on the wall is usually a revision behind. The four things that go wrong on arrival are the wrong flange form, the wrong face length, an NBR ring where Viton was ordered, and a fixed flange where a rotatable one was needed. All four are visible in thirty seconds with the parts on a bench.
A pre-order checklist you can print
Flange family, size, face length, seal compound, bakeout figure, fixed or rotatable. Six lines, and the joint stops being a surprise.
Match the clamp to the flange size, not the valve: aluminium toggle and rapid clamps to KF50, SS304 CNC clamps for KF16 to KF50, and chain clamps for KF80 to KF250.
Yes, all three name one joint. NW means nominal width, DN is its metric form, KF adds the clamp style. All three share the same 30 mm face and ring, and the same clamp.
Count rises with size: ISO63 takes 4, ISO100 and ISO160 take 8, ISO200 and ISO250 take 12, ISO400 and ISO500 take 16, ISO630 takes 20. Read the flange table, not the valve drawing.
No. The copper gasket yields once, and that yield is the seal. A second use gives a hardened ring that cannot conform. Check the knife edges and fit a new gasket each time.
Either, but the pattern is fixed: the non-rotatable half carries tapped holes and is fixed first, then a rotatable blank goes on the free side so the holes can be aligned.
Only up to the narrowest part of the path. A CF160 port behind a CF63 valve pumps like CF63. Check the adapter bore and the valve bore before buying a bigger port.
The flange question on a furnace is really a temperature question and an access question. Where the joint will be baked, CF earns its cost, because the seal is metal and stays metal. Where a fitter opens it weekly, KF earns its place, because one clamp beats sixteen bolts. In between, ISO-F covers the larger sizes and ISO-K the quicker ones, and the two never share hardware even when they share a bore. Decide the seal first, the family second, the size last, and write all three on the order.
Talk to a manufacturer who reads the drawing
EFUN builds vacuum valves and fittings in Wenzhou, China, in 304, 304L, 316L and 316LN, to drawings as well as to catalogue. Send a port size, a bakeout temperature and a face length, and we will tell you what fits.
Types of Vacuum Valves and How to Select the Right One
Roughing, foreline, poppet, gate, butterfly and ball valves compared by duty. Read this before choosing the body; read this article before choosing the joint.
Understanding Vacuum Valves: Fundamentals and Operating Principles
How a vacuum system is pumped down, and where each valve sits in the sequence. Useful background for anyone specifying a furnace for the first time.
Coming next in this series