S/S Pnematic actuator

C-TOP with AS-I
Hits:623
A.S-1 interface is an on--the-spot bus-masteringsystem, which can connect actuator and sensor(detector) to higtner control equipment (pmcipalcontroller).• Crea...

C-TOP with AS-I.jpgC-TOP connection units.jpg

A.S-1 interface is an on--the-spot bus-mastering

system, which can connect actuator and sensor

(detector) to higtner control equipment (pmcipal

controller).

Creating a ~I network requires electricaJ

source, one or several main control modules,

bus cable (actuating cable) and C-Top

prepared for AS-I connection (special built-in

card, connection cable, isolated displacement

connector)

Voflage of AS-t on-the~pot concentration line is

supplied by elecbical source.

Sensor and electromagnetic valve are controlled

by main oontrof module.

Each principal controller OOIWeys information to

PlC and can control up to 31 C-Top units

Interconnection is realized through actuating

cable. Actuating cable is used to convey

information and is also used for supplyilg

electrical source for electromagnetic vatve and

detector.

C-Top of AS-I version must be installed with

inductive detector and 24V DC.

Connect C-Top aotuating cable to bus cable

through isolated displacement connector,

therefore, it is Not required to connect each

C-Top to control system through cable.

concentration line can be used to connect

sensor to electromagnetic valve( actuator) in a

simple, fast and ecoNomical way. Reduction in

cabling wor1<1oad facilijates factory's assembly

and startup greatly, even shortening startup time

and avoiding some installation mistakes that

might occur.

Parts are same as standard C-Top. Only

changed parts are built-in card, connection

cable and connector itself of AS-I insulation

disp~cement connector.

Single action: one electromagnetic valve

Double action: two electromagnetic valves

An~mtxing dual seat valve: three

electromagnetic valVes

Open or closed valve position: one inductive

detector,two inductive detectors

lifting (Double seat, anti-mixing valve): three

inductive detectors

Valve position: open, closed, lower position lifting

valve used for washing

Maximum C-Top unit: 31 group (or auxiliary)

Connection cable.: 2m

Bus cable: maximum 1m

Bus cable (excluded): 21ines are used for data

and 30V DC voltage.

~~card specification: 2.1

~~ card maximum capacity: 4 input and

4 output (4 electromagnetic valves and 4

detectors)

 pneumatic actuator with C-TOP-1.png